LINQ BENCH V1.1
SPECIFICATIONS AND PERFORMANCE DATA
Relevant specifications for LINQ Bench can be found below
last updated:
Specifications
PHYSICAL | Core Bench | Standard Bench |
---|---|---|
Envelope Dimensions | 980mm (W) X 980mm(D) X 940-945mm(H) | 980(W) x 980(D) x 940-945(H) |
Bench Top Area | 980mm (W) x 750mm(D) | 980mm (W) x 750mm(D) |
Weight | 125KG (BENCH ONLY, EXCLUDING SCARA,RAIL,RAIL PLATFORM) | 200KG |
Max Bench top Weight Load | 200 kg | |
Robot Weight | 32Kg | |
Linear Rail Weight (1.5m) | 25kg | |
Linear Rail Platform Weight | 10kg | |
OPERATING CONDITIONS | ||
Temperature Range | 15C – 30C | |
Relative Humidity | 15% – 55% (no condensing, non-corrosive, indoors) | |
CENTRAL POWER SUPPLY | ||
System Input Voltage | 100 – 250 VAC 50-60 Hz, | |
Absolute Max. Output Current | 8A | |
Maximum Inrush Current: | 225A / Bench | |
Power Control | Master Power Switch | |
TRANSPORT LAYER POWER REQ. | ||
Power Requirements | 100 – 250 VAC 50-60 Hz | |
Maximum Current | 1.8A | |
CONNECTIVITY | ||
Data | Ethernet | |
Wireless Connectivity | None | |
Instrument Connection Types | Ethernet, USBA, Serial, I/O | |
COMPLIANCE AND CERTS: | CE, UKCA, UL, TUV |
Front and Side Elevations
Bench | mm |
---|---|
Width | 980 |
Height | 940 – 945 |
Depth | 750 |
SCARA Bench | mm |
---|---|
Width | 980 |
Depth | 230 |
Note: Height varies based on feet adjustment. See the height range provided.
Performance Data
# | Automation Performance | Transport Layer / Shuttle | SCARA arm | SCARA rail |
---|---|---|---|---|
1 | Mean Time Between Failure | 2 Years continuous usage, 8 hours per day, 5 days per week. (typical 1 year maintenance cycle provided within service contract) | > 2 years continuous usage, 8 hours per day, 5 days per week. (typical 1 year maintenance cycle provided within service contract | > 2 years continuous usage, 8 hours per day, 5 days per week. (typical 1 year maintenance cycle provided within service contract |
2 | Maximum Payload | 0.5kg | PF3400 – 2.5kg PF400 – 500g | N/A |
3 | Maximum Magnetic Field | 0.0002 T at Benchtop 0.272 T max at Shuttle Top Surface 0.058 T max at Transport Layer Surface | N/A | N/A |
4 | Labware Maximum Height | 250mm (i.e. 120mm vial in 225mm rack, produces a maximum assembled height of 250mm) | 250mm (i.e. 120mm vial in 225mm rack, produces a maximum assembled height of 250mm) | 250mm (i.e. 120mm vial in 225mm rack, produces a maximum assembled height of 250mm) |
5 | Supported Labware | All labware suitable for automation | All labware suitable for automation | All labware suitable for automation |
6 | End Effectors Available | N/A | AVAILABLE AS STANDARD: 1. Precise Gripper (SBS landscape and portrait formats accepted)2. Precise Tube Gripper3. ISO Plate Fixing for 3rd Party End Effectors | N/A |
7 | # of axis | 2 | 4 | 1 |
8 | Repeatability | N/A | +/- 0.1mm | +/- 50 μm |
9 | Cycle Time | Centre-Centre Lateral Time: 25s Centre-Centre Front/Back Time: 25s | 25 x 300 x 25mm pic and place with 1kg payload, 1.4seconds | 700mm / second |
10 | Maintenance Service Period | 6 months | 6 months | 6 months |